Toshiba Hardwired In/Out Online Tower UPS

Toshiba 1600XPi 14kVA / 11.9KW 208/240V Hardwired In/Out Online Tower UPS

$21,849.90 Sale Save

Only 2 left in stock

The 1600XP/XPi Series is single-phase double-conversion UPS, available in a range of sizes: 3.6 kVA, 6.0 kVA, 8.0 kVA, 10.0 kVA, 14 kVA, 18 kVA, and 22 kVA. Available in a tower design solution with a LCD touch-screen display that provides unmatched access for UPS monitoring and control. As a double-conversion online UPS, supplies uninterrupted, clean single-phase power to critical systems over large input voltage deviations without resorting to battery backup.

The 1600XPi Single phase UPS is an on-line double conversion tower design UPS ranging in capacity from 3.6 to 22 kVA. Toshiba uninterrupible power supply is designed to meet the growing demand in the information technology, healthcare, industrial, broadcasting and retail markets. The 1600XPi UPS ensures clean power, no power interruption in the event of a power outage, matching black color, and is compatible with 19" server racks. The tower design solution with LCD touch-screen display provides unmatched access for UPS monitoring and control. Toshiba UPS solutions offer emergency backup power to protect vital electronic resources from today’s all-too often blackouts, brownouts and power surges.

    • Digital LCD Touchscreen Display
    • Hot Swappable Batteries
    • Internal Isolation Transformer
    • Wide Input Voltage Window
    • Wide Input Frequency Window
    • Input Power Factor > 0.95
    • Power Factor Correction
    • Output Power Factor 0.85
    • Optional Network Interface Card for Remote Monitoring/Control
    • Optional External Battery Cabinets
    • Optional Environmental Monitoring Device

Model Number H3BG2L140C61T
Capacity (kVA/kW) 14.0/11.9KW
Topology True On-Line, Double-Conversion

 

Input
Standard Voltage 208/240V
Optional Voltage N/A
Phase 1PH
Frequency 50/60HZ
Power Factor 0.95
DC Voltage 288V

 

Output
Standard Voltage 240/208/120V
Optional Voltage N/A
Phase 1PH
Frequency 50/60HZ
Power Factor 0.85
Voltage THD < 3% for linear load; < 6% for non-linear load
Overload Capacity Inverter: 125%-30 sec./150%-10 sec, Bypass: 125%-10 min./1000%-1 cycle

 

Environment
Temperature Range 32° to 104°F (0° to 40°C)
Humidity 30% to 90% Non-Condensing
Heat Rejection 6610 BTU/Hr
Full-Load Efficiency 0.85
Altitude 6600 ft. (2000 m) Maximum Without Derating
Audible Noise 60dBA @ 1 m Typical

 

Dimensions
Dimensions 17.5" x 36.1" x 39"
Weight 771lbs.
Color O'Brien Black
Monitoring Touchscreen Operator Interface, RS232 Port, Optional RemotEye® 4 Intelligent Monitoring System
Options Receptacle Panel Configurations, Environmental Monitoring Device (EMD)
Features Output Isolation Transformer, RS232 & Dry Contact Interface, Crest Factor of 3, Angled Terminal Blocks for Easy Installation, Casters for Mobility
Standards UL 1778, CUL
Warranty 3-Year On-Site Warranty; See Toshiba Warranty Policy for Full Details