Eaton 9PX 9PX8K 8kVA/7.2kW 208V Online Double Conversion Rack/Tower UPS
Eaton 9PX 9PX8K 8kVA/7.2kW 208V Online Double Conversion Rack/Tower UPS
Eaton 9PX 9PX8K 8kVA/7.2kW 208V Online Double Conversion Rack/Tower UPS
Eaton 9PX 9PX8K 8kVA/7.2kW 208V Online Double Conversion Rack/Tower UPS
Eaton 9PX 9PX8K 8kVA/7.2kW 208V Online Double Conversion Rack/Tower UPS
Eaton 9PX 9PX8K 8kVA/7.2kW 208V Online Double Conversion Rack/Tower UPS

Eaton 9PX 9PX8K 8kVA/7.2kW 208V Online Double Conversion Rack/Tower UPS

$7,389.90 Sale Save

Only 2 left in stock

Eaton 9PX 9PX8K 8kVA/7.2kW 208V Online Double Conversion Rack/Tower UPS

Eaton 9PX 9PX8K Specifications:
General
Topology Double-conversion online
Configuration Rack/Tower
Catalog Number 9PX8K
Color Black and silver
Rating (VA/Watts) 8000/7200
 
Diagnostics Full system self test at power up
UPS Bypass Yes, ships with MBP11K208
Dimensions (H x W x D, inches) 10.2 (6U) x 17.3 x 30.0
Dimensions (H x W x D, mm) 259 (6U) x 439 x 762
Weight (kg) 93
Weight (lbs) 205
Warranty 2 years
Rail Kit Included 4-post rail kit and tower pedastals included
Remote Emergency Power off (REPO) ROO/RPO: Rear deck emergency stop connectors (for remote on/off and power off)
Contents
(Ships with the following items)
9PX8KPM 8 kVA 3U UPS power module
9PXEBM240RT 3U extended battery module
MBP11K208 rear-mount maintenance bypass
Gigabit Network card (Network-M2)
4-post rail kit
User manual
Quick start guide
Tower pedestals
Intelligent Power Software Suite CD
RS-232 serial cable
USB cable
Cable gland for hardwire connection
Phillips head screw driver
Efficiency 94% with resistive load
 
Electrical Input
Connection
Hardwired - see manual for terminal block layout

Input Cord None; hardwired
Input Voltage Range Full load: 176-276V, Derating: 100-276V
Nominal Voltage 208V default (200/208/220/230/240/250V)
Frequency 50/60 Hz
Frequency Range 60 Hz: 50–70 Hz, 50 Hz: 40–60 Hz
Input Power Factor >99
Input Current Distortion <5%
 
Electrical Output
Nominal Voltage 208V default (200/208/220/230/240/250V)
Output voltage regulation ±1% steady-state
Voltage THD <2% for linear loads
Output Receptacles
(3) NEMA L6-30R

Hardwired - see manual for terminal block layout

Power Factor 0.9
Transfer Time 0 ms
Circuit Breaker (3) 30A for L6-30R
​
Note Configurations with more than 5 EBMs require the SC240RT super charger module
 
Optional Extended Battery Module 9PXEBM240RT
Battery Description Sealed, lead-acid; maintenance free
Maximum number of extended battery modules (EBM) Add up to 5 extended battery modules (EBM) with UPS; add up to 12 EBMs with SC240RT supercharger module
Battery Management ABM technology; 3-stage charging extends battery service life by 50% and provides advance warning for battery replacement
Battery Replacement Hot-swappable extended battery modules (EBMs); no internal batteries in UPS module
Start On Battery Cold-start enabled; first cold start is always forbidden
 
Communications
User Interface Graphical display. UPS status in a single view.
LEDs 4 status-indicating LEDs
Communication Ports RS-232 (RJ45) ports; USB port as standard (HID). 6-foot RS-232 and USB cables included
Communications Card Slots Gigabit Network Card (Network-M2) included
Power Management Software Eaton Intelligent Power Software Suite CD (included)
 
Environmental & Standards
RoHS Compliance Yes
Surge Protection IEEE ANSI C62.41 Cat B2
Heat Dissipation (BTU) Online: 1760
Battery: 2375
(BTU/hr; battery full charged, resistive load)
Audible Noise <45 dB at 1 meter
Operating Temperature 0 to 40°C (32°F to 104°F)
Safety markings CE / cULus / NOM
EMC Markings IEC 62040-2:2006 Cat C2 / CISPR22 Class A / FCC part 15 Class A
Storage Temperature 0 to 35°C (32°F to 95°F); without batteries: -15 to 60°C (5°F to 140°F)
Relative Humidity 0 to 95%
Altitude <1,000 meters for nominal power; 10% power derating every 1000 meters (up to 3000 meters)