Eaton 5P 5P750R 750VA/600W 120V 1U Line-interactive Rackmount UPS
Eaton 5P 5P750R 750VA/600W 120V 1U Line-interactive Rackmount UPS
Eaton 5P 5P750R 750VA/600W 120V 1U Line-interactive Rackmount UPS
Eaton 5P 5P750R 750VA/600W 120V 1U Line-interactive Rackmount UPS
Eaton 5P 5P750R 750VA/600W 120V 1U Line-interactive Rackmount UPS
Eaton 5P 5P750R 750VA/600W 120V 1U Line-interactive Rackmount UPS
Eaton 5P 5P750R 750VA/600W 120V 1U Line-interactive Rackmount UPS
Eaton 5P 5P750R 750VA/600W 120V 1U Line-interactive Rackmount UPS
Eaton 5P 5P750R 750VA/600W 120V 1U Line-interactive Rackmount UPS
Eaton 5P 5P750R 750VA/600W 120V 1U Line-interactive Rackmount UPS

Eaton 5P 5P750R 750VA/600W 120V 1U Line-interactive Rackmount UPS

$647.90 Sale Save

Only 0 left in stock

Eaton 5P 5P750R 750VA/600W 120V 1U Line-interactive Rackmount UPS 

General
Topology Line interactive
Configuration Rackmount / Wallmount
Color Black and silver
Rating (VA/Watts) 750/600
 
Diagnostics Full system self-test at power up
Dimensions (H x W x D, inches) 1.7 (1U) x 17.2 x 20.0
Dimensions (H x W x D, mm) 43.2 x 438 x 509
Weight (kg) 14.1
Weight (lbs) 31.1
Warranty 3 years on electronics, 3 years on batteries with Rail Kit Included 4-post rail kit
Remote Emergency Power off (REPO) ROO/RPO: Rear terminal block connector for remote on/off and power off
Contents
(Ships with the following items)
5P UPS
User manual CD
Intelligent Power Software Suite CD
Quick start guide
USB cable
RS-232 serial cable
4-post rail kit
Efficiency up to 97%
 
Electrical Input
Connection
(1) NEMA 5-15P

Input Cord 6 feet (1.8 meters)
Input Voltage Range 89–151 Vac (adjustable to 70–153 Vac)
Nominal Voltage 120 Vac (adjustable to 100/120/125Vac)
Frequency 50/60 Hz (auto-sensing)
Frequency Range 47–70 Hz (50 Hz system), 56.5–70 Hz (60 Hz system), 40-70 Hz in low-sensitivity mode
 
Electrical Output
Nominal Voltage 120V default (100/120/125V)
Output Receptacles
(5) NEMA 5-15R

On Utility Voltage Regulation 102–132 Vac
On Battery Voltage Regulation -10%, +6% of nominal
Output Frequency 50/60 Hz ±0.1 % (autosensing)
Load Segments Group 1: (2) 5-15R outlets; Group 2: (1) 5-15R outlet
view load segments application note
Communications
User Interface LCD graphical display
LEDs Load protected, on battery and fault
Communication Ports RS-232 (RJ45) ports; USB port as standard (HID). 6-foot RS-232 and USB cables included
Communications Card Slots One slot; Gigabit Network Card (Network-M2) is optional
Power Management Software Eaton Intelligent Power Software Suite CD (included)
 
Environmental & Standards
RoHS Compliance Yes
Heat Dissipation (BTU) Line: 82, Battery 389
Audible Noise <45 dB at 1 meter
Operating Temperature 0 to 35°C (32°F to 95°F)
Performance - Safety - EMC UL 1778, UL497A
Safety markings cULus, CE
EMC Markings IEC 62040-2 C1-C2 / EN 55024 / CISPR22 Class B / FCC part 15 Class B
Storage Temperature -15°C – 40°C (5°F – 104°F)
Relative Humidity 0–90% non-condensing
Altitude Up to 10,000 ft (3000m) without de-rating